T3AS SYSTEM CABLES
WE BUY AND SELL LOCAL DIRECTOR LDIR430  7140

T3AS SYSTEM 02-0123-4000

TEST RESOURCE SHELF CONNECTOR #

RARA PART NUMBER

CABLE LENGTH

DESCRIPTION

J901 – J928

T3AS­J9AB

VAR.

TX DATA OUTPUT ­DS1 #1 / RCV DATA INPUT ­DS1 #1 (22 GA.)[ONE CABLE REQUIRED PER CONNECTOR. SPECIFY CONNECTOR LABEL (P901 – P928) WHEN ORDERING]. ONLY 1 CIRCUIT WIRED.

J901 – J928

T3AS­J9AB­4

VAR.

TX DATA OUTPUTS ­DS1 #1­#4 / RCV DATA INPUTS ­DS1 #1­#4 (26 GA.)[ONE CABLE REQUIRED PER CONNECTOR. SPECIFY CONNECTOR LABEL (P901 – P928) WHEN ORDERING]. 4 CIRCUITS WIRED.

 

 

 

 

ADMINISTRATION SHELF CONNECTOR #

RARA PART NUMBER

CABLE LENGTH

DESCRIPTION

J870

T3AS40­J870

VAR.

OFFICE ALARM INTERFACE

J880

T3AS­J880

VAR.

FUSE ALARM CONNECTION

J890

T3AS­J890

VAR.

DS1 BITS CLOCK

J900

T3AS40­J900

VAR.

RS232 ADMIN PROC DEBUG PORT

 

 

 

 

 

 

 

 

HIGH DENSITY TEST SHELF CONNECTOR #

RARA PART NUMBER

CABLE LENGTH

DESCRIPTION

J913 – J920

T3AS­J9AB

VAR.

TX DATA OUTPUT ­DS1 #1 / RCV DATA INPUT ­DS1 #1 (22 GA.)[ONE CABLE REQUIRED PER CONNECTOR. SPECIFY CONNECTOR LABEL (P913 – P920) WHEN ORDERING]. ONLY 1 CIRCUIT WIRED.

J913 – J920

T3AS­J9AB­4

VAR.

TX DATA OUTPUTS ­DS1 #1­#4 / RCV DATA INPUTS ­DS1 #1­#4 (26 GA.)[ONE CABLE REQUIRED PER CONNECTOR. SPECIFY CONNECTOR LABEL (P913 – P920) WHEN ORDERING]. 4 CIRCUITS WIRED.

 

 

 

 

T3AS SYSTEM 02-0130-4000

REM. LOW SPEED INTERFACE SHELF CONNECTOR #

RARA PART NUMBER

CABLE LENGTH

DESCRIPTION

J1

T3AS­T1­TX

VAR.

T1 LINK CONN. CABLE­T1TX (22 GA.)

J3

T3AS­T1­RX

VAR.

T1 LINK CONN. CABLE­T1RX (22 GA.)

J4

T3AS­ALM

VAR.

ALARM CONN. CABLE

P3, P7, P11, P15, P19

T3AS­TXE

VAR.

TX EQUIPMENT DATA OUTPUT (26 GA.)[ONE CABLE REQUIRED PER CONNECTOR. SPECIFY CONNECTOR LABEL (P3, P7, ETC.) WHEN ORDERING]

P2, P6, P10, P14, P18

T3AS­TXF

VAR.

TX FACILITIES DATA OUTPUT (26 GA.)[ONE CABLE REQUIRED PER CONNECTOR. SPECIFY CONNECTOR LABEL (P2, P6, ETC.) WHEN ORDERING]

P1, P5, P9, P13, P17

T3AS­RXE

VAR.

RX EQUIPMENT DATA INPUT (26 GA.)[ONE CABLE REQUIRED PER CONNECTOR. SPECIFY CONNECTOR LABEL (P1, P5, ETC.) WHEN ORDERING]

P4, P8, P12, P16, P20

T3AS­RXF

VAR.

RX FACILITIES DATA INPUT (26 GA.)[ONE CABLE REQUIRED PER CONNECTOR. SPECIFY CONNECTOR LABEL (P4, P8, ETC.) WHEN ORDERING]

 

 

 

 

 

 

 

 

REM. HIGH SPEED INTERFACE SHELF CONNECTOR #

RARA PART NUMBER

CABLE LENGTH

DESCRIPTION

J1

T3AS­T1­TX

VAR.

T1 LINK CONN. CABLE­T1TX (22 GA.)

J3

T3AS­T1­RX

VAR.

T1 LINK CONN. CABLE­T1RX (22 GA.)

J4

T3AS­ALM

VAR.

ALARM CONN. CABLE

 

 

 

 

T3AS SYSTEM 02-0123-4700

 

 

 

 

TEST RESOURCE SHELF CONNECTOR #

RARA PART NUMBER

CABLE LENGTH

DESCRIPTION

J901 – J928

T3AS­J9AB

VAR.

TX DATA OUTPUT ­DS1 #1 / RCV DATA INPUT ­DS1 #1 (22 GA.)[ONE CABLE REQUIRED PER CONNECTOR. SPECIFY CONNECTOR LABEL (P901 – P928) WHEN ORDERING]. ONLY 1 CIRCUIT WIRED.

J901 – J928

T3AS­J9AB­4

VAR.

TX DATA OUTPUTS ­DS1 #1­#4 / RCV DATA INPUTS ­DS1 #1­#4 (26 GA.)[ONE CABLE REQUIRED PER CONNECTOR. SPECIFY CONNECTOR LABEL (P901 – P928) WHEN ORDERING]. 4 CIRCUITS WIRED.

 

 

 

 

 

 

 

 

ADMINISTRATION SHELF CONNECTOR #

RARA PART NUMBER

CABLE LENGTH

DESCRIPTION

J870

T3AS47­J870

VAR.

OFFICE ALARM INTERFACE

J890

T3AS­J890

VAR.

DS1 BITS CLOCK

J900

T3AS47­J900

VAR.

RS232 ADMIN PROC DEBUG PORT

 

 

 

 

 

 

 

 

HIGH DENSITY TEST SHELF CONNECTOR #

RARA PART NUMBER

CABLE LENGTH

DESCRIPTION

J913 – J920

T3AS­J9AB

VAR.

TX DATA OUTPUT ­DS1 #1 / RCV DATA INPUT ­DS1 #1 (22 GA.)[ONE CABLE REQUIRED PER CONNECTOR. SPECIFY CONNECTOR LABEL (P913 – P920) WHEN ORDERING]. ONLY 1 CIRCUIT WIRED.

J913 – J920

T3AS­J9AB­4

VAR.

TX DATA OUTPUTS ­DS1 #1­#4 / RCV DATA INPUTS ­DS1 #1­#4 (26 GA.)[ONE CABLE REQUIRED PER CONNECTOR. SPECIFY CONNECTOR LABEL (P913 – P920) WHEN ORDERING]. 4 CIRCUITS WIRED.

 

 

 

 

REM. HIGH SPEED INTERFACE SHELF CONNECTOR #

RARA PART NUMBER

CABLE LENGTH

DESCRIPTION

J1

T3AS­T1­TX

VAR.

T1 LINK CONN. CABLE­T1TX (22 GA.)

J3

T3AS­T1­RX

VAR.

T1 LINK CONN. CABLE­T1RX (22 GA.)